Commercial EV Charging Stations are now a common sight at many businesses. More drivers choose electric cars every year. They need a place to charge at work, while shopping, or during a trip. A good charging site can bring in extra income. It can also keep customers on site longer. This model is built for daily use. It works with card, app, and QR payments. Site owners can track power use and cost with clear reports. It is a practical choice for gas stations, hotels, offices, and retail plazas.
Commercial Electric Car Charger Parameters
| Product number | YG-60KW | YG-80KW | YG-120KW | |
| Detailed specification | rated power | 60KW | 80KW | 120KW |
| Charging equipment | User Interface | 7-inch LCD color display touchscreen | ||
| installation | Floor-standing/Down in down out | |||
| Routing mode device size | 635*423*1600(mm) | |||
| Input voltage | AC380V±20% | |||
| Input frequency | 45~65Hz | |||
| The output voltage | 200-750VDC | |||
| Single gun output current range | 200V-500V | 200V-500V | 200V-500V | |
| The output voltage | 0-90A | 0-120A | 0-160A | |
| Single gun output current range | 200V-750V | 200V-750V | 200V-750V | |
| The output voltage | 0-60A | 0-80A | 0-107A | |
| Charging equipment | Single gun output current range | 0-112A | 0-150A | / |
| Cable length | 5m | |||
| Electrical index | Measurement accuracy | Level 0.5 | ||
| Current limit protection value | ≥110% | |||
| Voltage regulation accuracy | ≤±0.5% | |||
| Steady flow accuracy | ≤±1% | |||
| Ripple coefficient | ≤±0.5% | |||
| effectiveness | ≥94.5% | |||
| Power factor | ≥0.99 (50% load or more) | |||
| Harmonic content THD | ≤5% (50% load or more) | |||
| Feature design | HMI | 7-inch LCD color display touch screen, LED indicator | ||
| Charging mode | Auto full / fixed power / fixed amount / fixed time | |||
| payment method | Credit card payment / APP payment /scan code payment | |||
| Communication Interface | Ethernet 2/3/4G (optional) | |||
| Safety design | Executive standard | GB\T 20234, GB/T 18487, GB/T 27930, NB\T 33008 | ||
| security function | Charge gun temperature detection, overvoltage protection, undervoltage protection, overload protection, short circuit protection, grounding protection, over temperature protection, low-temperature protection, insulation monitoring protection, polarity reverse connection protection, lightning protection, emergency stop protection, leakage protection | |||
| Environmental indicators | Operating temperature | -25°C~+50°C | ||
| Working humidity | 5%~95% non-condensing cream | |||
| Working elevation | <3000m | |||
| Protection level | IP54 | |||
| cooling method | Forced air cooling | |||
| Noise control | ≤60dB | |||
| MTBF | 100,000 hours | |||


Key Benefits of Commercial EV Charging Stations
- New income for site owners.A charger can bring in charging fees. It also keeps drivers on site longer. Shops, cafes, and nearby services may see more visits.
- Remote monitoring.Operators can check status online. They can see errors, usage, and payments without standing next to the unit. This saves time and cuts site visits.
- Easy growth.A site can start with one unit. More units can be added later. This fits business ev chargers that need to grow with traffic.
- Better power control.These commercial charging stations can manage load across units. This helps avoid high peak demand. It also protects the site’s electrical system.
- Clear reports.The system records charging time, energy use, and payment data. Owners can use these reports to plan price, staff, and power needs.
Daily Care for EV Charging Pile
- Keep the unit clean.Wipe the screen and outer body. Clear dust from vents. Good airflow helps the commercial ev chargers run at a safe temperature.
- Check cables and plugs.Look for cuts, bends, or loose parts. Damaged cables should be replaced early. This keeps users safe.
- Update software.New software can fix bugs and improve payment links. Updates also help communication stay stable.
- Check the cooling system.The fan and air paths should be free of dirt. Blocked airflow can cause heat problems and slow charging.
- Record error messages.Write down fault codes and times. This helps service teams find the cause fast. It also reduces downtime.


Real User Cases for EV Charging Pile
Case: Delivery fleet in Minnesota, USA.
A regional delivery company runs 30 electric vans. Winters are cold, often below -15°C. The company installed six 60kW commercial ev chargers at its depot, a full electric car charging station commercial setup. Vans charge overnight and during short breaks. The fleet manager, Mark R., said: “We were worried about winter charging. But these units start and run every time. Our vans are ready each morning. We cut fuel costs by about 40% in the first year. The payment report also helps us track each van’s energy use.”
The site uses fixed time mode at night to charge when power rates are low. During the day, drivers use app payment for quick top-ups. The 7-inch touchscreen makes it easy to start a session. The IP54 rating keeps the units safe from snow and rain. The company plans to add four more chargers next year as its fleet grows.

Commercial EV Charging Stations Manufacturer – YG Machinery
YG Machinery is a manufacturer of Commercial EV Charging Stations. We build these units in our own factory. This gives buyers direct pricing, stable quality, and fast delivery. Our team also makes the Spider Crawler Crane, Portable Screw Air Compressor, and Borewell Drilling Machine,etc. For a factory quote and price, send your inquiry today.【WhatsApp/WeChat/Phone/Skype】+86 13937183602